PurposeChildren may be tested with a variety of visual acuity (VA) charts during their ophthalmic care and differences between charts can complicate the interpretation of VA measurements. This study compared VA measurements across four pediatric charts with Sloan letters and identified chart design features that contributed to inter-chart differences in VA.MethodsVA was determined for right eyes of 25 adults and 17 children (4–9 years of age) using Crowded Kay Pictures, Crowded linear Lea Symbols, Crowded Keeler logMAR, Crowded HOTV and Early Treatment of Diabetic Retinopathy Study (ETDRS) charts in focused and defocused (+1.00 DS optical blur) conditions. In a separate group of 25 adults, we compared the VA from individual Kay Picture optotypes with uncrowded Landolt C VA measurements.ResultsCrowded Kay Pictures generated significantly better VA measurements than all other charts in both adults and children (p < 0.001; 0.15 to 0.30 logMAR). No significant differences were found between other charts in adult participants; children achieved significantly poorer VA measurements on the ETDRS chart compared with pediatric acuity tests. All Kay Pictures optotypes produced better VA (p < 0.001), varying from -0.38 ± 0.13 logMAR (apple) to -0.57 ± 0.10 logMAR (duck), than the reference Landolt C task (mean VA -0.19 ± 0.08 logMAR).ConclusionKay Pictures over-estimated VA in all participants. Variability between Kay Pictures optotypes suggests that shape cues aid in optotype determination. Other pediatric charts offer more comparable VA measures and should be used for children likely to progress to letter charts.

Highlights

  • In pediatric eye care the measurement of visual acuity (VA) is central to the diagnosis of refractive error,[1] amblyopia[2] and pathology.[3]

  • VA was determined for right eyes of 25 adults and 17 children (4–9 years of age) using Crowded Kay Pictures, Crowded linear Lea Symbols, Crowded Keeler logMAR, Crowded HOTV and Early Treatment of Diabetic Retinopathy Study (ETDRS) charts in focused and defocused (+1.00 DS optical blur) conditions

  • No significant differences were found between other charts in adult participants; children achieved significantly poorer VA measurements on the ETDRS chart compared with pediatric acuity tests

Read more

Summary

Introduction

In pediatric eye care the measurement of visual acuity (VA) is central to the diagnosis of refractive error,[1] amblyopia[2] and pathology.[3] factors such as the inability of many preschool children to name letters and individual differences in cognitive development complicate acuity measures.[4] a gold standard pediatric visual acuity system exists (the Electronic Visual Acuity (EVA) tester)[5] it is primarily used for clinical trials rather than mainstream clinical practice. Eye care providers need a clear understanding of differences between charts to allow for accurate interpretation of VA measurements

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.