Abstract
As DNA technology becomes increasingly sensitive, forensic laboratories are receiving more low-template DNA samples. These samples, already low in DNA content, become even more challenging to process as the available DNA becomes further reduced during the extraction step. In this study, two extraction modifications were tested to determine if the cause of DNA loss could be identified and mitigated. A double lysis technique was used to test for DNA loss in the sample collection substrate, and lysate eluates were re-extracted to determine DNA loss from inefficient binding to the silica column. Both modifications showed DNA was lost at these steps. However, resulting STR profiles from these samples had fewer peaks and lower peak heights when compared to samples processed with no extraction modifications. Overall, the potential benefits of adding these extraction modifications for low-template DNA sample processing are not enough to justify the risk associated with additional manipulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.