Abstract

This research implements self-balancing robot using 3 algorithms. There are PID Controller, Ensemble Kalman Filter and Feed-Forward Control system. The PID controller function is as a robot equilibrium control system. The Kalman Ensemble algorithm is used to reduce noise measurement of accelerometer and gyroscope sensors. The PID controller and Ensemble Kalman filter were implemented on self-balancing robot in previous research. In this paper, we added the Feed-Forward controller that serves to detect disturbance derived from the unevenness of the ground. Disturbance is detected using 2 proximity sensors. Base on test results that the system can detect disturbance with an average delay of 2.15 seconds at Kff optimal value is 2.92. Feed-Forward effects result in self-balancing robots increasing power so that the pitch of the robot changes to anticipation of disturbance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.