Abstract
Phase aberration is one the key sources of image degradation in handheld B-mode ultrasound imaging. Sound speed heterogeneities create phase aberrations in the image by inducing additional tissue-dependent delays and diffractive effects that conventional beamforming does not incorporate. For this reason, the Fourier split-step angular spectrum method is used to simulate pressure fields in a heterogeneous sound speed medium and create B-mode images based on the cross-correlation of transmitted and received wavefields. Because the strongest aberrations are caused by a laterally varying sound speed profile, this work presents a new sound speed estimator that can be used to correct for aberrations in laterally varying media. Phantom experiments show a 58-76% improvement in point target resolution and a 2.5x improvement in contrast-to-noise ratio because of the proposed sound speed estimation and phase aberration correction scheme.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.