Abstract

The XENON1T experiment will probe a new parameter space in the direct dark matter search. Besides the enlargement of target mass to the ton scale, a further background reduction with respect to its predecessor XENON100 is necessary. A major contribution to the intrinsic contamination is the β-decaying isotope 85Kr, which leads to the requirement of a concentration less than 0.2 ppt of natural krypton in xenon. Its removal from the xenon gas is achieved by cryogenic distillation. For the new experiment a custom-build distillation column with a separation factor larger than 105 and a throughput of 3kg/h has been designed and built at the University of Muenster. Furthermore its performance has been characterized using different trace gas detection techniques, e.g. a novel 83mKr-tracer method, and its functionality has been tested successfully. The distillation column, which is installed and commissioned at the XENON1T experiment, is ready to process the 3.5 tons of xenon.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.