Abstract

NMR imaging was used to study dispersion in 6 mm bead pack. T 1 maps were employed to measure the rate of axial spreading of paramagnetic tracers (GdCl 3) inside the bead pack in the range of flow rate from 0.015 mL/s to 0.175 mL/s. From the T 1 maps, tracer concentration profiles were obtained, which yielded dimensionless axial dispersion coefficient and mean transit time. Spatial variations in the dispersion coefficient were observed at flow rates above 0.08 mL/s. We hypothesized that the observed spatial oscillations in the dispersion coefficient arise from the spatial variations of the velocity distribution. To validate this mechanism we showed by simulation that similar dispersion coefficient variation occur in a layered network.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.