Abstract

IntroductionThis study compared disinfection and shaping after root canal preparation with either XP-endo Shaper or TruNatomy instrument systems, supplemented by ultrasonic activation of sodium hypochlorite (NaOCl) with either stainless-steel (SS) or nickel-titanium (NiTi) inserts. MethodsMesial roots from mandibular molars with Vertucci class II configuration were divided into 2 groups (n = 24) based on anatomically paired micro-computed tomography (micro-CT) analyses. Pre and postpreparation micro-CT scans were obtained to evaluate the shaping performance. The canals were contaminated with a mixed bacterial culture for 30 days and then subjected to preparation with either XP-endo Shaper or TruNatomy instruments using NaOCl irrigation. Supplementary ultrasonic activation of NaOCl was conducted using either an SS (TruNatomy group) or NiTi (XP-endo Shaper group) insert. Bacteriological samples were taken from the canals before preparation (S1), after preparation (S2), and after the supplementary approach (S3). Bacterial reduction was evaluated using a quantitative real-time polymerase chain reaction. ResultsPreparation with both instrument systems significantly reduced bacterial counts (P < .01). After preparation, 36% (TruNatomy) and 35% (XP-endo Shaper) were negative for bacteria. These values increased to 59% and 65% after ultrasonic activation with the SS and NiTi inserts, respectively. The quantitative data in S2 showed that XP-endo Shaper promoted a significantly higher bacterial reduction than TruNatomy (P < .05). No significant intragroup differences were observed after ultrasonic activation (P > .05), probably because the SS insert promoted a significantly higher S2-to-S3 reduction than the NiTi insert (P < .01). Micro-CT analysis revealed no significant differences in the unprepared areas between the groups (P > .05). ConclusionsThe XP-endo Shaper caused a significantly higher bacterial reduction than TruNatomy in Vertucci class II canals. Better antibacterial results after ultrasonic activation were observed for the SS ultrasonic inserts than for the NiTi inserts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.