Abstract

This paper presents an improved direct power control (DPC) strategy of a wind turbine driven doubly fed induction generators (DFIGs) connected to distorted grid voltage conditions. A coordinate control strategy of the grid side converter (GSC) and rotor side converter (RSC) of the DFIG is designed to improve the overall scheme performance. The RSC is controlled based on a DPC principle to eliminate the electromagnetic torque and stator reactive power oscillations. The total active and reactive power oscillations are compensated by the GSC control to achieve constant active and reactive powers from the overall DFIG system. A current control scheme consisting of a proportional integral controller and a resonant compensator tuned at six the grid frequency is proposed to provide accurate control of the GSC current. The proposed control scheme removes rotor current regulators and the decomposition process of the rotor and GSC currents. In addition, the proposed scheme preserves the advantages of the classical DPC. The feasibility of the proposed DPC scheme is validated by simulation studies on a 1.5MW wind power generation system under harmonically distorted grid voltage conditions. The performance of the proposed and conventional DPC schemes is compared under the same operating conditions. The proposed scheme results show significant improvements in the scheme performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.