Abstract
The direct electrochemistry of myoglobin (Mb) has been observed at a glassy carbon (GC) electrode coated with silica sol-gel-encapsulated Mb film. A well-behaved cyclic voltammogram is observed with a midpoint potential (E(1/2)) of -0.25 V vs Ag/AgCl in a pH 7.0 phosphate buffer. This potential, which is pH-dependent, is 70-90 mV more negative than the formal potential values obtained by using the spectroeletrochemical titration method at the same pH. Square wave voltametry (SWV) also shows a peak potential of -0.25 V for the reduction of Mb under the same experimental conditions. Both cathodic and anodic peak currents have a linear relationship with the scan rate. The midpoint potential decreases with pH, having a slope of -30 mV/pH. UV-vis and resonance Raman spectroscopic studies reveal that the sol-gel provides a bio-compatible environment where Mb retains a structure similar to its solution form, a 6-coordinated aquomet myoglobin. These results suggest that the silica sol-gel is a useful matrix for studying direct electrochemistry of other heme proteins.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.