Abstract
To avoid the lock-in effect, a body dither is introduced for the ring laser gyro (RLG). A dither feedback signal is necessary to control the dither drive signal. In the current dither control method, a piezoelectric or electromagnetic transducer is often used to obtain the dither feedback. The read-out signal of the RLG contains all dither-related information; hence, dither feedback can be obtained from the read-out signal, and external feedback can be reduced. A novel dither controlling method without external feedback is introduced in the present paper. How to control the dither amplitude and track the resonant frequency of the dither motor is described in detail. A comparative experiment is conducted between the old dither control method and the new one. Results show that the output of RLG using the new method has the same accuracy as that using the old method, aside from having more compact circuit dimensions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.