Abstract

Macro amounts of fluoride in aluminium reduction materials are successfully determined with a fluoride electrode. Except for anhydrous aluminium fluoride, which requires fusion with sodium hydroxide, samples are dissolved in aqueous media. Cryolite and sodium fluorosilicatc are dissolved in boiling sodium hydroxide solution. Other materials containing fluoride, such as fluorspar and the reduction cell bath and pot-lining, require dissolution in a hydrochloric acid solution of aluminium chloride. Potential interference from large amounts of aluminium (and calcium, if present) is eliminated and pH control attained by using ammoniacal sulphosalicylate (and EDTA). The procedures are reasonably rapid. Relative errors of less than 2% and a relative standard deviation of 1% are achieved.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.