To evaluate the influence of the restorative approach and aging time on dentin bond strength (BS), failure mode (FM), and bottom/top microhardness ratio (B/T) in a large dentin cavity model. A total of 102 bovine incisors were used to produce models of conical dentin cavities (4.0mm thickness × 4.8mm top diameter × 2.8mm bottom diameter), which were restored using semi-direct filling (SDF) (Filtek™ Z250 XT + Scotchbond™ Universal/RelyX™ Ultimate luting system), direct bulk filling (DBF) (Filtek™ One Bulk Fill), and direct incremental filling (DIF) (Filtek™ Z250 XT) techniques. B/T, BS, and FM (n = 17) were analyzed in a microhardness tester, a universal testing machine, and a stereomicroscope, respectively, after 24h and 6months of water storage. BS and B/T data were analyzed using two-way ANOVA/Tukey post-hoc test (p < 0.05), while FM data were analyzed descriptively. There was a statistically significant difference in BS between the restorative techniques, and BS was influenced by aging time in the DBF and SDF groups. Mixed failure was predominant for the SDF technique in both aging times. There was no statistically significant difference in B/T among the restorative approaches regardless of the aging time (p > 0.05). Although all restorative approaches provided similar B/T, the semi-direct technique showed better performance on the material bond strength to dentine in large cavities.