Abstract
This research evaluates the effect of the variables of Phased Array Ultrasonic Testing(PAUT) on the sectoral angular beam scans “S-Scan” and the geometric morphology of planar discontinuities such as the inclination forthe ultrasonic beam and the shape of the extremity on accuracy in measurements. The study was carried out in two stages. Duringthe first stage, eight ASTM A36 steel samples with machined notches by penetration from EDM and a welded sample with lack of penetration in a butt weld were designed and produced. In the second stage, it wasmeasured the size of the discontinuities using ultrasound inspection and different configurations of the phase arrangement. The effect of each variable and inspection setting with errors between 0.2 % and 120 % were determined by statistical analysis.