Abstract

Aim. The aim of the present study was to compare the dimensional accuracy of stone casts obtained with vinyl polysiloxane molds through the double-impression technique with three pours into the same mold. Methods. A stainless steel master model was constructed simulating a three-unit fixed prosthesis. Twelve impressions were taken of this master model with addition silicone, using the double-impression technique. Three pours of type IV gypsum were then made into each mold, thus producing 36 casts. The pours were made 1 hour, 6 hours and 24 hours after the impression procedure. Next, intra- and interabutment measurements were made in a coordinate measuring machine. Results. Comparative analysis of the dimensional accuracy of stone casts resulting from multiple pours was not statistically significant in pours first and second (P > 0.05). These values, however, were statistically significant at third pour in the height in abutment 1 and upper distance interabutment. Conclusion. The wait time (1 hour, and 6 hours) observed before pouring the stone into the same molds did not cause significant dimensional accuracy of the casts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.