Abstract

Digitally captured signatures (DCS) are entering the scope of the Forensic Handwriting Examiner (FHE), and the meaningful comprehension and comparison of the captured information is essential in order to proceed to the examination of authenticity of DCS. In DCS solutions, force is captured and presented as pressure levels, but the relation between exercised force and the assigned pressure levels is not provided by the manufacturers of these solutions. For this purpose, we constructed an experimental array that allows the correlation of exercised force and assigned pressure levels, in a combination of three different digitizers, six different styli and four different capturing software. This process let us calculate the correlation function that assigns pressure levels to force for each solution (called the Zeta Function). Through this process, it was observed that different solutions follow different Zeta functions. To address this problem, a methodology for normalization of captured data between different solutions was created and demonstrated, using the calculated Zeta function and its inverse.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.