Abstract

To determine the distribution of stenoses and results of angioplasty in patients with similar forearm dialysis grafts made of polytetrafluoroethylene (PTFE). Diagnostic radiographs of the fistula obtained in 215 patients were reviewed; 90 patients had similar, unrevised forearm PTFE loop dialysis grafts. The location, morphology, and results of angioplasty were reviewed for each measurable stenosis. Surgical, radiologic, and dialysis records were reviewed to document the subsequent patency rate of each patient's dialysis access. On the initial diagnostic fistulogram, 93 stenoses were identified. The anatomic distribution included 47% at the venous anastomosis and 11% within 1 cm of the anastomosis. Life table analysis revealed a 6-month patency rate of 63% and a 1-year patency rate of 41% for the first angioplasty in a given graft, and a 6-month patency rate of 44% and a 1-year patency rate of 22% [corrected] for the second angioplasty. Performance of serial venous angioplasty procedures may help prolong the life of a graft, but the patency rates diminish with subsequent interventions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.