Abstract

A stator malfunction occurs due to insulation damage, which means that the stator is directly connected to the power supply, and a direct connection is the direct cause of a major accident. For this reason, a lot of research is being done to identify faults. In recent years, studies on Motor Electrical Signature Analysis are being performed, sensorless methods for fault diagnosis of the stator of an induction motor. However, it has problems with it, it has the difficulty in interpreting multi-faults and in detecting an inter-turn short circuit of a stator. This paper suggested a tool that can diagnose 2-turn short circuit, through the relationship between self-inductance and mutual inductance in the synchronous reference frame of a D-Q transformation.