Abstract

Neonatal sepsis is defined as an infection-related condition characterized by signs and symptoms of bacteremia within the first month of life. It is the leading cause of mortality and morbidity among newborns. While several studies have been conducted in other parts of world to assess the usefulness of complete blood count parameters and hemogram-derived markers as early screening tools for neonatal sepsis, the associations between sepsis and its complications with these blood parameters are still being investigated in our setting and are not yet part of routine practice. To evaluate the diagnostic significance of complete blood cell count hemogram-derived novel markers for neonatal sepsis among neonates attending public hospitals in the southwest region of Oromia, Ethiopia, through a case control study. A case control study was conducted from October 2021 to October 2023 Sociodemographic, clinical history, and laboratory test results data were collected using structured questionnaires. The collected data were entered into Epi-data 3.1 version and exported to SPSS-25 for analysis. Chi-square, independent sample t-test, and receiver operator characteristics curve of curve were used for analysis. A P-value of less than 0.05 was considered statistically significant. In this study, significant increases were observed in the following values in the case group compared to the control group: In white blood cell (WBC) count, neutrophils, monocyte, mean platelet volume (MPV), neutrophils to lymphocyte ratio, monocyte to lymphocyte ratio (MLR), red blood cell width to platelet count ratio (RPR), red blood width coefficient variation, MPV to RPR, and platelet to lymphocyte ratio. Regarding MLR, a cut-off value of ≥ 0.26 was found, with a sensitivity of 68%, a specificity of 95%, a positive predictive value (PPV) of 93.2%, and a negative predictive value (NPV) of 74.8%. The area under the curve (AUC) was 0.828 (P < 0.001). For WBC, a cut-off value of ≥ 11.42 was identified, with a sensitivity of 55%, a specificity of 89%, a PPV of 83.3%, and a NPV of 66.4%. The AUC was 0.81 (P < 0.001). Neutrophils had a sensitivity of 67%, a specificity of 81%, a PPV of 77.9%, and a NPV of 71.1%. The AUC was 0.801, with a cut-off value of ≥ 6.76 (P = 0.001). These results indicate that they were excellent predictors of neonatal sepsis diagnosis. The findings of our study suggest that certain hematological parameters and hemogram-derived markers may have a potential role in the diagnosis of neonatal sepsis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.