Abstract

PurposeTo evaluate the diagnostic performance of three different cardiac stress protocols for myocardial perfusion imaging (MPI) using a cadmium-zinc-telluride (CZT) camera with invasive coronary angiography (ICA) correlation for the diagnosis of coronary artery disease in a high risk population. MethodsRetrospective study of 263 patients (96 women and 167 males, mean age 68 years) from which 119 patients performed a bicycle stress test (BST), 113 pharmacological stress test (PST) and 31 a combination of the two (CST) between September 2014 and December 2018. The patients then underwent myocardial perfusion imaging (MPI), followed by ICA and evaluated by means of quantitative angiography software, within six months after the MPI. The mean pre-test probability score for coronary disease according to the European Society of Cardiology criteria was 36% for the whole population. The MPI was performed in a dedicated CZT cardio camera (D-SPECT Spectrum Dynamics) with a two-day protocol, according to the European Association of Nuclear Medicine guidelines. ResultsNo significant difference was observed between the three stress protocols in terms of diagnostic accuracy (BST 85%, PST 88%, CST 84%). The overall diagnostic accuracy of MPI to identify patients with any obstructive CAD at ICA was 86%, Sensitivity 93%, Specificity 54%, PPV 90% and NPV 63%. ConclusionThe CZT D-SPECT camera achieves overall satisfactory results in the diagnosis of CAD, observing no significant differences in the diagnostic performance when the stress test was performed as a BST, PST or CST.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call