Abstract
Objective: To assess the diagnostic accuracy of fine-needle aspiration (FNA) and frozen section (FS) in nodular thyroid disease. Setting: Tertiary care academic medical center. Study Design: Retrospective review of 139 consecutive patients undergoing surgery for nodular thyroid disease. FNA and FS sensitivity, specificity, and accuracy were calculated with respect to permanent section histology. Results: Among 63 patients with an FNA interpreted as either benign (n = 38) or malignant (n = 25), FNA was accurate (sensitivity 89%, specificity 97%, accuracy 94%). FS identified only one case of carcinoma missed by FNA. Among 76 patients with a “suspicious” FNA, FS was reasonably accurate (sensitivity 67%, specificity 100%, accuracy 89%), but was deferred in 50% of cases. Conclusion: Given high FNA accuracy, more selective use of FS is suggested. Significance: The study results will assist with intra-institutional patient counseling and intraoperative decision-making with respect to FNA and FS results in patients with nodular thyroid disease. (Otolaryngol Head Neck Surg 2001;124:531-6.)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have