Abstract

To improve the accuracy of the stator winding fault diagnosis in induction motor, a new diagnostic method based on the Hilbert-Huang transform (HHT) was proposed. The ratio of fundamental zero sequence voltage to positive sequence voltage after switch-off was selected as the stator fault characteristic, which could effectively avoid the influence of the supply unbalance and the load fluctuation, and directly represent the asymmetry in the stator. Using the empirical mode decomposition (EMD) based on HHT, the zero sequence voltage after switch-off was decomposed and the fundamental component was extracted. Then, the fault characteristic can be acquired. Experimental results on a 4-kW induction motor demonstrate the feasibility and effectiveness of this method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.