Abstract

Micro pixel chambers (μ-PIC) are gaseous two-dimensional imaging detectors originally manufactured using printed circuit board (PCB) technology. They are used in MeV gamma-ray astronomy, medicalimaging, neutron imaging, the search for dark matter, and dose monitoring. The position resolution of the present μ-PIC is approximately 120 μm (RMS), however some applications require a fine position resolution of less than 100 μm. To this end, we have started to develop a μ-PIC based on micro electro mechanical system (MEMS) technology, which provides better manufacturing accuracy than PCB technology. Our simulation predicted the gains of MEMS μ-PICs to be twice those of PCB μ-PICs at the same anode voltage. We manufactured two MEMS μ-PICs and tested them to study their behavior. In these experiments, we successfully operated the fabricatedMEMS μ-PICs and we achieved a maximum gain of approximately 7×103 and collected their energy spectra under irradiation of X-rays from 55Fe. However, the measured gains of the MEMS μ-PICs were less than half of the values predicted in the simulations. We postulated that the gains of the MEMS μ-PICs are diminished by the effect of the silicon used as a semiconducting substrate.

Highlights

  • Tron imaging applications require a position resolution of less than 100 μm and MeV gamma-ray astronomy requires precise tracking of charged particles with an angular resolution of less than 5◦

  • Micro electro mechanical system (MEMS) technology enables the use of thicker substrates compared with those for printed circuit board (PCB) technology

  • The substrates used in MEMS technology comprise silicon, which is a semiconductor; the effect of a semiconducting substrate being substituted for the insulating substrate of μ-PICs should be investigated

Read more

Summary

Introduction

Tron imaging applications require a position resolution of less than 100 μm and MeV gamma-ray astronomy requires precise tracking of charged particles with an angular resolution of less than 5◦. Because of the limitation of the manufacturing accuracy of PCB technology, the diameter of μ-PIC anode vias is limited to approximately 50 μm. A more advanced technology is needed for manufacturing fine-pitch μ-PICs. Micro electro mechanical system (MEMS) technology is one such capable technology. A MEMS μ-PIC is expected to exhibit a fine position resolution and a high gas gain. We manufactured two MEMS μ-PICs to investigate their behavior. We report the results of both the simulations and experiments

Simulation study of MEMS μ-PIC
Measurements of the gas gains of MEMS μ-PICs
Summary
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call