Abstract
BackgroundThe Finnish neurological function testing battery for dogs (FINFUN) was developed to meet the increasing demand for objective outcome measures in veterinary physiotherapy. The testing battery should provide consistent, reproducible results and have established face and content validity. Internal consistency and intra- and inter-rater reliability of the FINFUN were also investigated.ResultsThe FINFUN comprised 11 tasks: lying, standing up from lying, sitting, standing up from sitting, standing, proprioceptive positioning, starting to walk, walking, trotting, walking turns and walking stairs. A score from 0 to 4, (0: unable to perform task, 4: performing task with normal motor function) was given for each task, the maximum score being 44. Twenty-six dogs were filmed when performing the FINFUN. Seven observers scored the performances from the video recordings. The FINFUN was considered to have appropriate face and content validity based on a pilot study, clinical experience and critical reflection of the development process. Its internal consistency was excellent, with no Cronbach’s alpha values below 0.922. The intra-rater reliability for total score of experienced observers was almost perfect: 0.999 (observer 1) and 0.994 (observer 2). The inter-rater reliability for both experienced and novice observers’ total scores was also almost perfect (0.919–0.993). Analysis of each individual task showed substantial intra-rater and inter-rater agreement for the tasks “lying” and “sitting”.ConclusionsThe FINFUN is an objective, valid and reliable tool with standardized scoring criteria for evaluation of motor function in dogs recovering from spinal cord injury.
Highlights
The Finnish neurological function testing battery for dogs (FINFUN) was developed to meet the increasing demand for objective outcome measures in veterinary physiotherapy
Magnetic resonance imaging or myelography confirmed the diagnosis in all dogs, and 22 dogs had surgical hemilaminectomy and 2 dogs dorsal laminectomy prior to the physiotherapy referral
Face and content validity The FINFUN was considered to meet the criteria for good face and content validity
Summary
The Finnish neurological function testing battery for dogs (FINFUN) was developed to meet the increasing demand for objective outcome measures in veterinary physiotherapy. The testing battery should provide consistent, reproducible results and have established face and content validity. Veterinary physiotherapy is an important part of the modern treatment regime for these neurological patients [3]. Objective evaluation of motor function and change over time is important and requires accurate and repeatable measurements and reliable instruments [8]. Human neurological physiotherapy has several established, validated and reliable functional outcome measures for patients with spinal cord injury and stroke that are used in both clinical practice and research [8,9,10,11,12].
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have