Abstract

The article presents a method for equipment designing and techniques to reduce methane ignition hazard, excessive dust in the place of operation and in conveyor transportation lines as well as methods to eliminate the risk of coal dust explosion. It describes technical solutions, the effects of these solutions and tests’ results related to effectiveness of the described air-water solutions as well as water spraying devices. The spraying systems used in longwall shearers and roadheaders, on conveyor belt transfer points as well as the spraying curtains in the roadways are described. A new approach to the assessment of the safety level in the zones protecting against coal dust explosion hazard is also given. Intensity of dust accretion along the explosion protecting zones is analyzed. The spraying device is suggested, the operation of which depends on dust concentration in the ventilation air. The article presents the results of tests on the effectiveness in dust reduction and suppression of methane ignition. The tests were carried out in the laboratory, on testing facilities and in-situ.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.