Abstract

Industrial single photon emission tomography system utilized the gamma-ray emission of radioactive tracer to images the cross-section of tracer distribution for industrial process monitoring and diagnosis. In this paper, 36 units of Sodium Iodide, NaI scintillation detectors were used to study flow in a pipelines. The detectors were arranged in two geometrical arrangement, a hexagon and nonagon configuration. The detectors are connected to three 12-channel gamma counter which is controlled by data acquisition and image reconstruction software developed for the system. The images from these two set-ups were also compared with single detector time-average system. Depending on the size of the pipeline used, i.e. for 36 detectors, the nonagon arrangement gives more information on the distribution of the tracer. Thus nonagon set-up is more suitable to be used for representing or demonstrating the image of the tracer distribution in the pipeline.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.