Abstract
A simple and sensitive analytical method for the quantitative determination of buspirone in rat plasma by HPLC with fluorescence detection was developed and validated using naproxen as an internal standard. A relatively small-volume (150 µL) aliquot of rat plasma sample was prepared by a simple deproteinization procedure using acetonitrile as a precipitating organic solvent. Chromatographic separation was performed using Kinetex® C8 column with an isocratic mobile phase consisting of acetonitrile and 10-mM potassium phosphate buffer (pH 6.0) at a flow rate of 1.0 mL/min. The eluent was monitored by fluorescence detector at a wavelength pair of 237/380 nm (excitation/emission). The linearity was established at 20.0-5000 ng/mL, and the limit of detection was 6.51 ng/mL. The precision (≤14.6%), accuracy (89.2-108%), and stability (89.1-101%) were within acceptable ranges. The newly developed method was successfully applied to intravenous and oral pharmacokinetic studies of buspirone in rats.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.