Abstract
ObjectivePeripheral artery disease is the second most common cardiovascular disease. It can often occur in complex form when there is a presence of long, diffuse, and multiple lesions. Current treatments use either single long drug-coated balloons (DCBs) or multiple DCBs; however, treatment success is limited. The purpose of this study was to investigate the preclinical feasibility of our multiple-release Tailored Medical Devices DCB (MR-TMD-DCB) to treat multiple arterial segments using a single DCB. MethodsThe MR-TMD-DCBs were developed using a two-layer coating approach. The DCBs were developed in a certified Current Good Manufacturing Practices facility using presterilized materials and reagent and then characterized for coating morphology, thermal and chemical changes, and in vitro particulate shedding. The drug loss, tissue uptake, and undelivered drug amounts were analyzed using an in vitro peripheral artery flow model and explanted pig arteries. Then, an in vivo survival study was performed using a healthy porcine model to measure the short-term drug uptake (seven swine; 14 treatments at day 1) and retention (seven swine; 14 treatments at day 7) in two different arterial segments after treatment with a single MR-TMD-DCB. ResultsThe coating on the MR-TMD-DCB was smooth and homogeneous with paclitaxel molecularly dispersed in its amorphous state. A negligible number of particulates were shed from the MR-TMD-DCB coating. A similar amount of drug was accurately delivered into two separate explanted arteries using a single MR-TMD-DCB during the in vitro flow model testing (707 ± 109 ng/mg in the first explanted artery and 783 ± 306 ng/mg in the second explanted artery). The MR-TMD-DCB treatment resulted in equivalent drug amounts in the two arterial segments at day 1 (63 ± 19 ng/mg in the first treatment site and 59 ±19 ng/mg in the second treatment site) and at day 7 (9 ± 6 ng/mg in the first treatment site and 10 ± 6 ng/mg in the second treatment site). In addition, the drug levels at each time point were in the clinically relevant range to prevent neointimal hyperplasia. ConclusionsThe MR-TMD-DCBs provided equivalent and clinically relevant drug retention levels into two different arterial segments. Thus, MR-TMD-DCBs can be used to accurately deliver drug into multiple arterial segments with the use of a single DCB. The clinical outcomes of these findings need further investigation. Future long-term pharmacokinetics and safety studies will be performed to evaluate the safety and efficacy of the MR-TMD-DCB.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.