Abstract

In the current paper we describe a novel sample preparation technique termed dispersive liquid-phase microextraction for the preconcentration and determination of 2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol (dicofol) and its degradation products in water samples that includes 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethene(2,4′-DDE), 1,1-dichloro-2,2-bis(4-chlorophenyl)ethane(4,4′-DDE) and 1,1,1-trichloro-2-(2-chlorophenyl)-2-(4-chlorophenyl)ethane (2,4′-DDT) coupled with gas chromatography mass spectrometry (GC-MS), in which a new ionic liquid 1,3-diisooctylimidazolium hexafluorophosphate abbreviated as [D(i-C8)IM][PF6] was used as extraction solvent. For each one extraction, 1.00 mL of the methanol solution containing 40 µL of the ionic liquid was sprayed into 25.00 mL of water sample. In the meantime the ionic liquid was finely dispersed into the aqueous phase and analytes were rapidly migrated into the ionic liquid. After the solution was centrifuged for 2 min at 5000 rpm, the droplets of the ionic liquid are subsided in the bottom of the conical test tube (30.0 ± 0.2 µL). Moreover, the factors relevant to extraction efficiencies were investigated and optimised including the volume of the ionic liquid, disperser solvent, extraction time, sample pH and ionic strength. Under optimal conditions, the enrichment factors of the extraction were between 550 and 725 with an extraction efficiency ranging from 66% to 87% for each different analyte. Finally, 1.0 µL of the ionic liquid collected from above extraction was injected into the injector block of GC-MS instrument for analysis. The detection limit (S/N = 3), the relative standard deviations for 2.0 µg L−1 of the standard analyte (n = 5) and linearity in a calibration range were found to be 3–8 ng L−1, 1.0–2.7% and 10–3000 ng L−1, respectively. Good spiked recoveries over the range of 92.0–13.5% were obtained. The proposed method offers the advantages of simplicity of operation, rapidity, good extraction efficiency and enrichment factor; it has been successfully applied to determination of dicofol and its degradation products in environmental water samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.