Abstract
China Spallation Neutron Source (CSNS) cryogenic system provides supercritical cryogenic hydrogen for two moderators of the target station. The commissioning work of the cryogenic system is mainly divided into four steps:(1) the acceptance test of the helium refrigerator, using the refrigerator internal heater as thermal load, and verify whether the helium refrigerator refrigerating capacity meet the requirements of the contract or not; (2) Helium commissioning, using dummy load to simulate the dynamic heat load of the moderator, and system cool down to 20K with He instead of H2. (3) Hydrogen commissioning based on the step 2, while system is cooled down to 20K with hydrogen as working medium. (4) Joint Commissioning with two moderators. So far, the CSNS cryogenic system has completed all commissioning work and finished four rounds of stable operation for the commissioning of the target station and spectrometer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.