Abstract

An autotrophic denitrification system was developed for treatment wastewater from steel industry. The aim was to evaluate the kinetics and capability of the system in reducing nitrate content in such industrial wastewater. The experiments were conducted in batch suspension and continuous runs. The denitrification kinetics in suspension runs obeys first order reaction with the rate constant k1 and k2 were determined to be 0.014 and 0.004 g-N/m3.d, respectively. The continuous runs used a column packed with mixture of granular sulfur and limestone. The microbes of Thiobacillus denitrificans were attached on the surface of granular sulfur in the form of biofilm. The biofilm thickness was investigated to be approximately 40 μm. The denitrification kinetics in the packed column obeys half-order reaction with the rate constant k of 0.172 g-N1/2.m1/2/(kg-S.d). The lower denitrification extent of industrial wastewater compared with the synthetic wastewater might be due to the lack of alkalinity. Keywords: Autotrophic denitrification, sulfur, packed column, thiobacillus denitrificans.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.