Abstract

In this paper, a novel electrical time domain reflectometry (ETDR) measurement technique capable of measuring moisture distribution profile in a porous medium is presented. A signal calibration algorithm to interpret the ETDR waveform based on an empirical relation between moisture content and differential impedance of the medium was developed. The transient distribution of the moisture content in a concrete block covered with fibre reinforced polymer laminate on one end surface was experimentally measured. The experimental results were then compared with the solution of a finite element analysis. Good agreement was shown for the trend of the transient moisture distribution profile. It was demonstrated that the ETDR distributed moisture sensor developed in the current study was capable of measuring the variation of the moisture content distribution in a porous medium.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call