A full differential strip readout multi-gap RPC was developed to meet high counting rate and high multiplicity requirements of a high collision rate experiments as Compressed Baryonic Matter at the future FAIR facility. The Multi-Gap, Multi-Strip Resistive Plate Chamber (MGMSRPC) is a completely symmetric two stack structure with time resolution around 50 ps and a detection efficiency better than 95%. A very good efficiency and time resolution at counting rates exceeding the CBM-TOF requirements is obtained using low resistivity (~ 1010 Ωcm) glass electrodes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.