Abstract

Various washing systems combined with chlorinated water, ozonated water, ultrasonic waves, and spray washing were developed to increase the efficiency of surface sterilization of leafy lettuce. Leafy lettuce treated with 100 mg.L -1 , 150 mg.L -1 and 200 mg.L -1 chlorinated water for 20 min decreased microbial load by 90%-99%. Samples treated with ozonated water (1.0-1.5 mg.L -1 ) at 4°C for 30 min decreased microbial load by 99%. Ozone treatment for 60 min resulted in 99.9% reduction in coliforms. The solubility of ozone increased with the reduction in water temperature and is very compatible with a hydrocooling system. Ultrasonic wave, vortex and spray washing techniques decreased microbial load, however none achieved greater than a 90% reduction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.