Abstract
We report on the development of a custom particle detection system that aims to improve the detection capabilities of the ROSPHERE array. The detector is designed specifically for lifetime measurements using the in-beam Fast-timing method for nuclear states in nuclides produced in nuclear transfer reactions. An 80 x 3.6 mm disc of BC400 plastic scintillator was coupled to a sparse SiPM array readout connected to a dedicated Front End Electronics board. The detector was tested versus a conical LaBr3(Ce) coupled to a Hamamatsu PMT readout. The timing measurements resulted in a resolution of 896(5) ps. The detector design, characteristics, and performances are presented in this paper along with future improvements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.