Abstract

The Maxim's Electron Scatter Chamber (Maxim Chamber) was developed to obtain uniform dose distribution when applying electron beam (e-beam) irradiation to materials of irregular surface. This was achieved by placing a stainless steel mesh surrounding a cylindrical area where the target sample was placed. Upon contact with the mesh, electrons scatter and are directed onto the target from multiple angles, eliminating the e-beam linearity and resulting in a uniform dose distribution over the target surface. The effect of irradiation in the Maxim Chamber on dose distribution and pathogen reduction was tested on rabbit carcasses to simulate other larger carcasses. The dose uniformity ratio (DUR) on the rabbit carcasses was 1.8, indicating an acceptable dose distribution. On inoculated carcasses, this treatment reduced Escherichia coli O157:H7 by >5 log cycles. These results indicate that carcass irradiation using e-beam is feasible using the Maxim's electron scattering chamber. Appropriate adjustments will be further needed for commercial application on beef and other animal carcasses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.