Abstract

We are developing a neutron beam monitor with a gas electron multiplier (GEM) for the high-intensity total diffractometer at J-PARC. In order to analyze the basic characteristics of the GEM-based detector, a neutron irradiation test was carried out at J-PARC. The wavelength-spectrum distribution obtained from the test is consistent with the calculations, and the beam profiles agree with the simple Monte Carlo (MC) simulation. The position resolution of the GEM-based detector is estimated to be approximately 1.2mm. Therefore we found that as a neutron beam monitor, the GEM-based detector has good two-dimensional imaging ability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.