Abstract

AbstractWe have been developing a low energy Ne atom scattering system combined with a time-of-flight spectrometer for insulator surface structural analysis. Insulator surface structure is difficult to study because of charging effects during electron or ion beam bombardment. Structural analyses of insulator surfaces are very important in fundamental research as well as technology fields. In our system, charged ion beams of 2 keV-Ne+ are converted into neutral beams by charge exchange with the same element gas after the primary beam passes through a chopper. Other features of this system are pulsed beams, time-of-flight measurements, and a micochannel plate (MCP) detector is coaxially mounted along the primary beam. This is a home made equipment. We will show the detection systems, as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.