Abstract
Abstract Herein, we investigated the effect of a dielectric film on the transmission spectrum of a bar-type flat cutoff probe (BCP). By conducting electromagnetic wave simulations, we found that placing a dielectric film with a thickness of 1 mm or less on the sensor did not affect the measurement of the BCP under thin sheath condition. However, a film thickness of 1 mm or more results in a low-frequency shift in the cutoff frequency. The shift in the cutoff frequency was related not only to the film thickness, but also to the dielectric constant of the film and sheath width, which could be understood through a circuit model of the BCP. The calculated results were experimentally validated using alumina plates of various thicknesses. Consequently, our findings demonstrate that measuring the electron density on a BCP is feasible even when a dielectric film is deposited, thereby improving the accuracy of the measurement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.