Abstract

The development of an automated pneumatic transfer system used to quickly acquire data from materials irradiated with a deuterium–tritium (DT) neutron generator is described in this paper. This system was designed to gather data on short-lived activation and fast-fission products, and was used to characterize the generator’s neutron field. The average sample transit time between irradiation and data acquisition is 363.9 ms at an average velocity of 30.92 m/s (101.3 ft/s). The neutron flux profile as a function of depth into the sample capsule is shown to decrease exponentially, having a maximum flux value of 5.662 × 108 ± 0.056 × 108n/cm2 s. The average DT neutron energy in the system’s sample geometry was determined to be 14.250 ± 0.011 MeV using a unique zirconium–niobium “sandwich” technique. A flux surface equation is also presented as a function of accelerator voltage and deuterium beam current. Methods of analysis are discussed with a proof of a linear flux profile assumption for thin foils.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call