Abstract
In previous research, we developed a three-dimensional (3D) boundary magnetic charge method (BMCM) for high-accuracy field calculations in a static magnetic field, even when there exist great differences between the magnitudes of permeability between neighboring magnetic materials. This method, however, cannot be applied to a system that contains saturated magnetic materials. In the present study, therefore, we have developed a novel method that addresses this issue. According to this new method, we divide the region containing the magnetic material into small-volume elements and divide the boundaries between neighboring small-volume elements into small-surface elements, assigning each element an appropriate initial value of permeability. The magnetic field inside and outside of the magnetic material is calculated using this permeability. The value of the permeability of each element is iteratively updated using μ–H data. The updated value of the permeability after the i-th iteration, μi, is compared with that of the previous value, μi−1. If the difference between the two values is within a preset range, the iteration process is judged to have converged and the value of μi is regarded as the final converged value of the permeability. The magnetic field at an arbitrary point in space and/or inside the body of the magnetic material is calculated from the converged permeability of each element. As a result, we have succeeded in developing a novel BMCM for the calculation of a static magnetic field with high accuracy in a system containing saturated magnetic materials.