We have developed a 500-kV, 10-mA photocathode DC gun for energy recovery linac (ERL) light sources. A segmented ceramic insulator with guard rings is employed to improve robustness at high voltage operation, because this structure can prevent field emission electrons from directly striking the ceramic surface. We have recently succeeded in applying 500 kV on the ceramics for eight hours without any discharge. This high voltage testing was performed with a simple configuration without NEG pumps, cathode and anode electrodes to mainly study the field emission from a tube supporting the cathode electrode. The same high voltage testing with a full configuration necessary for beam generation was carried out up to 380 kV where some increase of radiation was observed. Up-to-date status of our gun development is presented in detail.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.