Abstract

An accurate, simple, reproducible, and sensitive liquid chromatographic method was developed and validated for the captopril determination in controlled release tablets. The analyses were performed at room temperature on a reversed-phase Phenomenex Luna C18 column (250 mm × 4.6 mm). The mobile phase was composed of water:methanol (45:55; v/v) pH 2.5, and it was eluted isocratically at a 1.0 mL min−1 flow rate. The method was validated in terms of specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. The response was linear in the range 0.3–1.5 mg mL−1 (r 2 = 0.9983). The relative standard deviation values for inter-and intra-day precision were 0.77% and 0.50%, respectively. Recoveries ranged between 97.7 and 99.1%. The method was successfully applied for the determination of captopril in the developed formulations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.