Abstract

A simple, very fast, precise and accurate reverse phase ultra performance liquid chromatographic method was developed for the determination and validation of topotecan hydrochloride in bulk and injection dosage form. A Waters BEH C18, 50×2.1 mm, 1.7 μm particle size column in gradient mode was used with mobile phase comprising of 0.1% v/v orthophosphoric acid in water and acetonitrile. The analytical column was thermostated at 50° and flow rate was set at 0.4 ml per min, with photo diode array detection at 260 nm. The retention time of topotecan was found 1.38 min. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found linear between 20 to 60 μg/ml. The limit of detection and limit of quantification were found 0.2353 and 0.7131 μg/ml, respectively. Percentage recoveries were obtained in the range of 98.91% and 99.17%. The proposed method is precise, accurate, selective and reproducible. The ultra performance liquid chromatographic assay procedure, which proved superior because of its greater sensitivity and relatively shorter (4 min) run time, should be an important tool for speedy future analysis of topotecan hydrochloride in bulk and its injection dosage form.

Highlights

  • A simple, very fast, precise and accurate reverse phase ultra performance liquid chromatographic method was developed for the determination and validation of topotecan hydrochloride in bulk and injection dosage form

  • Linearity was studied by preparing standard solutions of topotecan hydrochloride at different concentration levels

  • A known amount of topotecan standard was added into pre-analysed injection and subjected to the proposed ultra performance liquid chromatographic (UPLC) method

Read more

Summary

Introduction

Et al.: UPLC Method for Topotecan Hydrochloride A simple, very fast, precise and accurate reverse phase ultra performance liquid chromatographic method was developed for the determination and validation of topotecan hydrochloride in bulk and injection dosage form. The ultra performance liquid chromatographic assay procedure, which proved superior because of its greater sensitivity and relatively shorter (4min) run time, should be an important tool for speedy future analysis of topotecan hydrochloride in bulk and its injection dosage form. Topotecan hydrochloride and its injection is official only in Indian Pharmacopoeia[1].

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.