Abstract

The development and validation of an online cytochrome P450 (CYP)-based bioreactor coupled to automated solid-phase extraction (SPE) and gradient HPLC separation is described. The analytical method was checked on intra- and inter-day repeatability of the ethoxyresorufin- O-demethylation (EROD) reaction with CYP 1A1/1A2 containing β-NF induced rat liver microsomes as an enzyme source. These experiments showed that CYP activity was linearly decreased with 16% over an 11 h period. Inter-day measurements had a CV of 9.1%. Furthermore, K m and V max values of the EROD reaction, measured with the bioreactor, were 2.72 ± 0.46 μM and 7.9 ± 0.5 nmol/min/mg protein, respectively. These were in good correspondence with K m and V max values, measured with standard batch assay, which amounted 0.66 ± 0.08 μM and 6.4 ± 0.2 nmol/min/mg protein respectively. In conclusion the newly developed analytical method can be used effectively and at a microliter scale for online generation, extraction and separation of metabolites.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.