Abstract

Recombinant human growth hormone (rhGH) is a peptide comprising 191 amino acids, that is mainly used to promote the growth of children and plays an important antiaging role. In the present study, a simple and sensitive quantitation method for rhGH in rat plasma was established by LCMS/MS. After simple and rapid enzymatic digestion of the plasma sample, two suitable surrogate peptides (LFDNAMLR and FPTIPLSR) were selected for quantitative analysis. The results showed good linearity over calibration range 10–2000 ng/mL. The quality control (QC) accuracy ranged from −13.8 to 14.3%, and the accuracy of the lower limit of quantification (LLOQ) ranged from −12.9 to 19.0%. The intra-day and inter-day precision ranges for all QCs were 1.7–13.6% and 4.0–7.0%, respectively. The method was successfully applied to intravenous and subcutaneous pharmacokinetic studies in rats. In comparison with previously published methods, our method features simple sample preparation combined with a short sample processing time (3.5 h), wide linear range (10–2000 ng/mL), small plasma volume (35 μL), and LLOQ (10 ng/mL).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.