Abstract
Protection for the Korea superconducting tokamak advanced research (KSTAR) is somewhat more complicated than for the previous tokomak generation. External reasons for this increased complexity are the initial and maintenance costs, and internal reasons relate to various characteristics of the tokamak and long pulse operation. KSTAR has two protection mechanisms: the device protection system protects damage to superconducting coils etc. from events within the other systems, and the fast protection system protects the internal vacuum vessel components against damage from heating and the long pulse plasma.The fast protection system initially contained the plasma control system (PCS), central control system (CCS), and the heating devices. In 2012, a fast interlock interface was implemented for PCS fail-safe. This detected the absence of plasma current using the diagnostic signals and discharge operation gate windows of the timing synchronized system (TSS), and activates the operation gates and heating stop from the CCS. Additional fast interlock logic was implemented to reduce damage to the plasma facing components (PFC) and other materials by overheating and improper operational state of heating systems after starting the discharge sequence. However, the fast interlock interface system has failed to protect the heating during PCS malfunctions since 2013.This paper introduces the KSTAR protection system, and describes the fast protection interface, with testing and operational results, then discusses future plans for a more effective and safer protection system.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have