Abstract

Fire smoke decontamination equipment, such as fire-fighting robots and smoke exhaust robots, is mainly used in long and narrow spaces such as underground garages. In several recent decades, the study of fire smoke spread in narrow spaces and fire smoke decontamination equipment stimulated the interests of many researchers. However, present equipment cannot eliminate insoluble toxic gases such as CO and may decrease the height of the smoke layer, causing great difficulty to rescue. In this study, a novel mobile fire smoke decontamination process and system are proposed. The experimental study and theoretical prediction of the system are conducted. The results show that the developed equipment is able to eliminate fire smoke particles and CO, cool the space, and improve the visibility of the fire site. The developed equipment can reduce the space temperature to below 60 °C, reduce the CO concentration to below 145 ppm, and enhance the visibility to more than 50 m in the rectangular tunnel after operating for 30 min under 4 MW fire condition.