Abstract

In the present analytical study a rapid, robust and specific reversed-phase HPLC method has been developed and validated for quantitative estimation of amlodipine besylate in the dissolution study of oral films by direct injections of aqueous solutions. The study involved isocratic elution of amlodipine besylate in Zorbax® Eclipse XDB-C18 analytical column using buffer (0.7 % aqueous triethylamine adjusted to pH 3.0 with orthophosphoric acid) and methanol in the ratio of 40:60 (v/v). The aqueous solutions were analysed at a flow rate of 1.0 ml/min at 239 nm. The method presented linearity (r2= 0.999) in the concentration range 20-150 μg/ml. The result indicated good recoveries ranging from 98.06% to 99.22%. The method showed good precision with % Relative standard deviation value less than 2. All the validation parameters were within the acceptance range. The developed method can be successfully employed for in-vitro dissolution and routine analysis of formulations containing Amlodipine besylate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.