Abstract

Medical waste incinerator (MWI) fly ash is regarded as a highly toxic waste because it contains high concentrations of heavy metals and dioxins, including polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). Therefore fly ash from MWI must be appropriately treated before being discharged into the environment. A melting process based on a direct current thermal plasma torch has been developed to convert MWI fly ash into harmless slag. The leaching characteristics of heavy metals in fly ash and vitrified slag were investigated using the toxicity characteristic leaching procedure, while the content of PCDD/Fs in the fly ashes and slags was measured using method 1613 of the US EPA. The experimental results show that the decomposition rate of PCDD/Fs is over 99% in toxic equivalent quantity value and the leaching of heavy metals in the slag significantly decreases after the plasma melting process. The produced slag has a compact and homogeneous microstructure with density of up to 2.8 g/cm3.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.