Abstract

Background:The inter-rater reliability of the craniocervical flexion test (CCFT) has not been established.Objective:To investigate the intra-rater and inter-rater reliabilities of the CCFT in asymptomatic subjects.Methods:Sixty asymptomatic subjects were randomly selected for the study. The CCFT was measured on each subject by two testers for inter-rater reliability and by one of the testers after a gap of seven days for the intra-rater reliability. Before testing, the participants were trained for the movement and compensations were corrected.Results:The CCFT has high inter-rater reliability (intra-class correlation coefficient 0.907, standard error of mean 0.735) and high intra-rater reliability (intra-class correlation coefficient 0.986, standard error of mean 0.287). A Bland & Altman limits of agreement analysis has confirmed the high inter- and intra-rater reliabilities of the test.Conclusion:The CCFT has high inter-rater and intra-rater reliabilities in asymptomatic subjects.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.